English
Language : 

M16C65 Datasheet, PDF (490/829 Pages) Renesas Technology Corp – RENESAS MCU M16C FAMILY / M16C/60
Under development
M16C/65 Group
Preliminary Specification
This is a preliminary specification and is subject to change.
22. Remote Control Signal Receiver
22.2.6 PMCi Interrupt Source Register (PMCiINT) (i = 0, 1)
PMC0 Interrupt Source Register
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
PMC0INT
Address
01F5h
Bit Symbol
CPINT
REINT
DRINT
BFULINT
PTHDINT
PTDINT
TIMINT
SDINT
Bit Name
Compare match flag
interrupt enable bit
Receive error flag interrupt
enable bit
Data reception complete
interrupt enable bit
Receive buffer full flag
interrupt enable bit
Header match flag interrupt
enable bit
Data 0/1 match flag
interrupt enable bit
Timer measure interrupt
enable bit
Special data match flag
interrupt enable bit
0: Disabled
1: Enabled
0: Disabled
1: Enabled
0: Disabled
1: Enabled
0: Disabled
1: Enabled
0: Disabled
1: Enabled
0: Disabled
1: Enabled
0: Disabled
1: Enabled
0: Disabled
1: Enabled
Function
After Reset
00h
RW
RW
RW
RW
RW
RW
RW
RW
RW
PMC1 Interrupt Source Register
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
PMC1INT
Address
01FDh
After Reset
X000 X00Xb
Bit Symbol
Bit Name
Function
RW
—
(b0)
No register bit. If necessary, set to 0. Read as undefined value.
—
REINT
Receive error flag interrupt 0: Disabled
enable bit
1: Enabled
RW
DRINT
Data reception complete
interrupt enable bit
0: Disabled
1: Enabled
RW
—
(b3)
No register bit. If necessary, set to 0. Read as undefined value.
—
PTHDINT
Header match flag interrupt 0: Disabled
enable bit
1: Enabled
RW
PTDINT
Data 0/1 match flag
interrupt enable bit
0: Disabled
1: Enabled
RW
TIMINT
Timer measure interrupt
enable bit
0: Disabled
1: Enabled
RW
—
(b7)
No register bit. If necessary, set to 0. Read as undefined value.
—
REJ09B0484-0030 Rev.0.30 Sep 09, 2008