HC4GX15 Datasheet, PDF (637/668 Pages) Altera Corporation – HardCopy IV Device Handbook | |||
|
◁ |
Chapter 1: DC and Switching Characteristics of HardCopy IV Devices
1â7
Electrical Characteristics
The calibration accuracy for calibrated series and parallel OCTs are applicable at the
moment of calibration. If the voltage or temperature changes, the termination
resistance value varies. Table 1â9 lists the resistance tolerance for HardCopy IV OCT.
Table 1â9. I/O OCT Resistance ToleranceâPreliminary (Note 1)
Symbol
Description
Resistance Tolerance
Commercial Max Industrial Max Unit
ROCT_CAL Internal series/parallel OCT with calibration
(2)
ROCT_UNCAL Internal series/parallel OCT without calibration
TBD
â
%
â
%
Notes to Table 1â9:
(1) Pending silicon characterization.
(2) For resistance tolerance after power-up calibration, refer to Table 1â10.
Table 1â10 lists OCT variation with temperature and voltage after power-up
calibration. Use Table 1â10 and Equation 1â1 to determine the OCT variation when
voltage and temperature vary after power-up calibration.
Equation 1â1. OCT Variation Without Re-Calibration (Note 1)
ROCT
=
RCA
ï¦
Lï¨
1
+
d----R--
dT
Ã
ÎT
+
d----R--
dV
Ã
ÎVï¸ï¶
Note to Equation 1â1:
(1) RCAL is calibrated OCT at power up. ÎT and ÎV are variations in temperature and voltage with respect to temperature
and VCCIO values, respectively, at power up.
Table 1â10. OCT Variation after Power-Up CalibrationâPreliminary (Note 1), (2)
Symbol
Description
VCCIO (V)
Commercial
Typical
3.0
TBD
2.5
TBD
dR/dV
OCT variation with voltage without
re-calibration
1.8
TBD
1.5
TBD
1.2
TBD
3.0
TBD
2.5
TBD
dR/dT
OCT variation with temperature
without re-calibration
1.8
TBD
1.5
TBD
1.2
TBD
Notes to Table 1â10:
(1) Valid for VCCIO range of ± 5% and a temperature range of 0° to 85°C.
(2) Pending silicon characterization.
Unit
%/mV
%/°C
© June 2009 Altera Corporation
HardCopy IV Device Handbook Volume 4
|
▷ |