HC4GX15 Datasheet, PDF (142/668 Pages) Altera Corporation – HardCopy IV Device Handbook | |||
|
◁ |
9â4
Figure 9â3. Simplified POR Block Diagram
Chapter 9: Hot Socketing and Power-On Reset in HardCopy IV Devices
Power-On Reset Circuitry
Regulator POR
Monitored V CC Supplies (1) Satellite POR
PORSEL
POR PULSE
SETTING
(4 ms to 12 ms or
100 ms to 300 ms)
POR
Main POR
Note to Figure 9â3:
(1) For more details about these supplies, refer to Table 9â1.
The POR circuit monitors the power supplies specified in Table 9â1.
Table 9â1. Power Supplies Monitored by the POR Circuitry
Power Supply
Description
VCC
Core voltage and periphery circuitry power supply
VCCAUX (1)
Power supply for temperature sensing diode and POR circuitry
VC CP D
I/O pre-driver power supply
VC CP G M
Configuration pins power supply
Note to Table 9â1:
(1) This power supply is for the auxiliary power supply in Stratix IV devices.
Setting (V)
0.9
2.5
2.5, 3.0
1.8, 2.5, 3.0
The POR circuit does not monitor the power supplies listed in Table 9â2.
Table 9â2. Power Supplies Not Monitored by the POR Circuitry
Voltage Supply
Description
Setting (V)
VC CIO
VC CA _ PL L
VC CD _ P LL
VC C_ C LK IN
I/O power supply
PLL analog global power supply
PLL digital power supply
PLL differential clock input power supply (top and bottom
I/O banks only)
1.2, 1.5, 1.8, 2.5, 3.0
2.5
0.9
2.5
VC CB AT
Battery back-up power supply for design security volatile
N/A
key storage
The POR specification is designed to ensure that all circuits in the HardCopy IV
device are at certain known states during power up.
HardCopy IV Device Handbook, Volume 1