English
Language : 

HC4GX15 Datasheet, PDF (615/668 Pages) Altera Corporation – HardCopy IV Device Handbook
Chapter 3: HardCopy IV GX ALTGX_RECONFIG Megafunction User Guide
3–9
Dynamic Reconfiguration
Figure 3–5 shows page 5 of the ALTGX_RECONFIG MegaWizard Plug-In Manager.
Figure 3–5. MegaWizard Plug-In Manager—ALTGX_RECONFIG (Analog Controls)
Table 3–3 describes the available options on page 5 of the MegaWizard Plug-In
Manager for your ALTGX_RECONFIG custom megafunction variation.
Table 3–3. MegaWizard Plug-In Manager Options (Page 5) (Part 1 of 2)
ALTGX_RECONFIG Setting
Use ‘reconfig_address_out’
Use ‘reconfig_address_en’
Use ‘reset_reconfig_address’
Description
Reference
This option is enabled by default when you select the
Channel and TX PLL select/reconfig option. The value
on reconfig_address_out[5:0] indicates
the address associated with the words in the .mif,
which contains the dynamic reconfiguration
instructions. The dynamic reconfiguration controller
automatically increments the address at the end of
each .mif write transaction.
“Dynamic Reconfiguration
Controller Port List” section in
the HardCopy IV GX Dynamic
Reconfiguration chapter in
volume 3 of the HardCopy IV
Device Handbook
When high, this optional output status signal indicates
that the address to be used in the .mif write
transaction cycle has changed. This signal gets
asserted when the .mif write transaction is completed
(the busy signal de-asserted).
“Dynamic Reconfiguration
Controller Port List” section in
the HardCopy IV GX Dynamic
Reconfiguration chapter in
volume 3 of the HardCopy IV
Device Handbook
When asserted, this optional control signal resets the
reconfig_address_out (current
reconfiguration address) to 0.
“Dynamic Reconfiguration
Controller Port List” section in
the HardCopy IV GX Dynamic
Reconfiguration chapter in
volume 3 of the HardCopy IV
Device Handbook
© June 2009 Altera Corporation
HardCopy IV Device Handbook Volume 3