Bit 7—A/D End Flag (ADF): Status flag that indicates the end of A/D conversion.
Bit 7
ADF
0
1
Description
[Clearing conditions]
• When 0 is written in the ADF flag after reading ADF = 1
• When the DTC is activated by an ADI interrupt and ADDR is read
[Setting conditions]
• Single mode: When A/D conversion ends
• Scan mode: When A/D conversion ends on all specified channels
(Initial value)
Bit 6—A/D Interrupt Enable (ADIE): Selects enabling or disabling of interrupt (ADI) requests
at the end of A/D conversion.
Bit 6
ADIE
0
1
Description
A/D conversion end interrupt (ADI) request is disabled
A/D conversion end interrupt (ADI) request is enabled
(Initial value)
Bit 5—A/D Start (ADST): Selects starting or stopping of A/D conversion. Holds a value of 1
during A/D conversion.
The ADST bit can be set to 1 by software, a timer conversion start trigger, or the A/D external
trigger input pin (ADTRG).
Bit 5
ADST
0
1
Description
A/D conversion stopped
(Initial value)
Single mode: A/D conversion is started. Cleared to 0 automatically when conversion
on the specified channel ends
Scan mode: A/D conversion is started. Conversion continues sequentially on the
selected channels until ADST is cleared to 0 by software, a reset, or a
transition to standby mode or module stop mode
Bit 4—Scan Mode (SCAN): Selects single mode or scan mode as the A/D conversion operating
mode. See section 20.4, Operation, for single mode and scan mode operation. Only set the SCAN
bit while conversion is stopped.
634