English
Language : 

HD64F2149 Datasheet, PDF (458/1035 Pages) Renesas Technology Corp – Hitachi 16-Bit Single-Chip Microcomputer
Bit 4
FER
Description
0
[Clearing condition]
(Initial value)*1
When 0 is written in FER after reading FER = 1
1
[Setting condition]
When the SCI checks the stop bit at the end of the receive data when reception ends,
and the stop bit is 0 *2
Notes: 1. The FER flag is not affected and retains its previous state when the RE bit in SCR is
cleared to 0.
2. In 2-stop-bit mode, only the first stop bit is checked for a value of 0; the second stop bit
is not checked. If a framing error occurs, the receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial reception cannot be continued while the
FER flag is set to 1. In synchronous mode, serial transmission cannot be continued,
either.
Bit 3—Parity Error (PER): Indicates that a parity error occurred during reception using parity
addition in asynchronous mode, causing abnormal termination.
Bit 3
PER
Description
0
[Clearing condition]
(Initial value)*1
When 0 is written in PER after reading PER = 1
1
[Setting condition]
When, in reception, the number of 1 bits in the receive data plus the parity bit does not
match the parity setting (even or odd) specified by the O/E bit in SMR*2
Notes: 1. The PER flag is not affected and retains its previous state when the RE bit in SCR is
cleared to 0.
2. If a parity error occurs, the receive data is transferred to RDR but the RDRF flag is not
set. Also, subsequent serial reception cannot be continued while the PER flag is set to
1. In synchronous mode, serial transmission cannot be continued, either.
424