English
Language : 

HD6417750RF240DV Datasheet, PDF (852/1132 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH™ RISC engine Family / SH7750 Series
Section 17 Smart Card Interface
SH7750, SH7750S, SH7750R Group
(3) Standby Mode and Clock
When switching between smart card interface mode and standby mode, the following procedures
should be used to maintain the clock duty cycle.
Switching from Smart Card Interface Mode to Standby Mode:
1. Set the SBP1IO and SBP1DT bits in SCSPTR1 to the values for the fixed output state in
standby mode.
2. Write 0 to the TE and RE bits in the serial control register (SCSCR1) to stop transmit/receive
operations. At the same time, set the CKE1 bit to the value for the fixed output state in standby
mode.
3. Write 0 to the CKE0 bit in SCSCR1 to stop the clock.
4. Wait for one serial clock cycle. During this period, the duty cycle is preserved and clock output
is fixed at the specified level.
5. Write H'00 to the serial mode register (SCSMR1) and smart card mode register (SCSMR1).
6. Make the transition to the standby state.
Returning from Standby Mode to Smart Card Interface Mode:
7. Clear the standby state.
8. Set the CKE1 bit in SCSCR1 to the value for the fixed output state at the start of standby (the
current SCK pin state).
9. Set smart card interface mode and output the clock. Clock signal generation is started with the
normal duty cycle.
Normal operation
Standby mode
Normal operation
123
4 56
7 89
Figure 17.13 Procedure for Stopping and Restarting the Clock
Page 800 of 1076
R01UH0456EJ0702 Rev. 7.02
Sep 24, 2013