LPC Interface Bridge Registers (D31:F0)
10.8.3.6
LV2 â Level 2 Register
I/O Address:
Default Value:
Lockable:
Power Well:
PMBASE + 14h
(ACPI P_BLK+4)
00h
No
Core
Attribute:
Size:
Usage:
RO
8-bit
ACPI or Legacy
10.8.3.7
Bit
Description
Reads to this register return all 0s, writes to this register have no effect. Reads to this register
7:0
generate a âenter a level 2 power stateâ (C2) to the clock control logic. This will cause the STPCLK#
signal to go active, and stay active until a break event occurs. Throttling (due either to THTL_EN or
FORCE_THTL) will be ignored.
NOTE: This register should not be used by Intel iA64 processors or systems with more than 1 logical processor,
unless appropriate semaphoring software has been put in place to ensure that all threads/processors
are ready for the C2 state when the read to this register occurs
LV3âLevel 3 Register (Mobile Only)
I/O Address:
Default Value:
Lockable:
PMBASE + 15h (ACPI P_BLK + 5)
Attribute:
00h
Size:
No
Usage:
Power Well:
RO
8-bit
ACPI or Legacy
Core
10.8.3.8
Bit
Description
Reads to this register return all 0s, writes to this register have no effect. Reads to this register
7:0 generate a âenter a C3 power stateâ to the clock control logic. The C3 state persists until a break
event occurs.
NOTE: If the C4onC3_EN bit is set, reads this register will initiate a LVL4 transition rather than a LVL3
transition. In the event that software attempts to simultaneously read the LVL2 and LVL3 registers
(which is illegal), the ICH6 will ignore the LVL3 read, and only perform a C2 transition.
NOTE: This register should not be used by iA64 processors or systems with more than 1 logical processor,
unless appropriate semaphoring software has been put in place to ensure that all threads/processors
are ready for the C3 state when the read to this register occurs.
LV4âLevel 4 Register (Mobile Only)
I/O Address:
Default Value:
Lockable:
PMBASE + 16h (ACPI P_BLK + 6)
Attribute:
00h
Size:
No
Usage:
Power Well:
RO
8-bit
ACPI or Legacy
Core
Bit
Description
Reads to this register return all 0s, writes to this register have no effect. Reads to this register
7:0 generate a âenter a C4 power stateâ to the clock control logic. The C4 state persists until a break
event occurs.
NOTE: This register should not be used by iA64 processors or systems with more than 1 logical processor,
unless appropriate semaphoring software has been put in place to ensure that all threads/processors
are ready for the C4 state when the read to this register occurs.
410