English
Language : 

SH7713 Datasheet, PDF (590/904 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7700 Series
Section 16 Serial Communication Interface with FIFO (SCIF)
Initial
Bit
Bit Name Value
R/W
Description
2
PER
0
R
Parity Error
In asynchronous mode, indicates that there is a
parity error or not in the data read from SCFRDR.
0: There is no parity error in the receive data read
from SCFRDR
[Clearing conditions]
• Power-on reset or manual reset
• When there is no parity error in SCFRDR read
data
1: There is a parity error in the receive data read
from SCFRDR
[Setting condition]
When there is a parity error in SCFRDR read data
Rev.1.50 Aug. 30, 2006 Page 550 of 860
REJ09B0288-0150