Section 3 DSP Operating Unit
3.4.4 Memory Data Formats
Memory data formats that can be used in the DSP instructions are classified into word, and
longword. An address error will occur if word data starting from an address other than 2n or
longword data starting from an address other than 4n is accessed by MOVS.L, LDS.L, or STS.L
instruction. In such cases, the data accessed cannot be guaranteed
An address error will not occur if word data starting from an address other than 2n is accessed by
the MOVX.W or MOVY.W instruction. When using the MOVX.W or MOVY.W instruction, an
address must be specified on the boundary 2n. If an address is specified other than 2n, the data
accessed cannot be guaranteed.
3.4.5 Instruction Formats of Double and Single Transfer Instructions
The format of double data transfer instructions is shown in tables 3.12, and that of single data
transfer instructions in table 3.13.
Rev.1.50 Aug. 30, 2006 Page 103 of 860