English
Language : 

SH7670 Datasheet, PDF (999/1292 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7670 Series
Section 22 Serial Communication Interface with FIFO (SCIF)
Serial
data
Start
1 bit
0 D0
Data
Parity Stop Start
bit bit bit
D1
D7 0/1 1
0 D0
Data
Parity Stop
bit
bit
1
D1
D7
0/1 1
Idle state
(mark state)
RDF
FER
RXI interrupt
request
One frame
Data read and RDF flag
read as 1 then cleared to 0
by RXI interrupt handler
ERI interrupt request
generated by receive
error
Figure 22.9 Example of SCIF Receive Operation
(8-Bit Data, Parity, 1 Stop Bit)
5. When modem control is enabled, the RTS signal is output when SCFRDR is empty. When
RTS is 0, reception is possible. When RTS is 1, this indicates that SCFRDR exceeds the
number set for the RTS output active trigger.
Figure 22.10 shows an example of the operation when modem control is used.
Serial data
RxD
Start
bit
0 D0 D1 D2
Parity
bit
D7 0/1 1
Start
bit
0 D0 D1
D7 D1
RTS
Figure 22.10 Example of Operation Using Modem Control (RTS)
Rev. 1.00 Nov. 14, 2007 Page 973 of 1262
REJ09B0437-0100