Serial Data Reception: Figure 16.11 shows a sample flowchart for serial reception.
Use the following procedure for serial data reception after enabling the SCIF for reception.
Start of reception
1. Receive error handling and
break detection: Read the DR,
ER, and BRK flags in
Read ER, DR, BRK flags in
SCFSR2, and the ORER flag
SCFSR2 and ORER
in SCLSR2, to identify any
flag in SCLSR2
error, perform the appropriate
error handling, then clear the
DR, ER, BRK, and ORER
ER or DR or BRK or ORER
Yes
= 1?
flags to 0. In the case of a
framing error, a break can also
be detected by reading the
value of the RxD2 pin.
No
Error handling 2. SCIF status check and receive
data read : Read SCFSR2 and
Read RDF flag in SCFSR2
check that RDF = 1, then read
the receive data in SCFRDR2,
No
RDF = 1?
read 1 from the RDF flag, and
then clear the RDF flag to 0.
The transition of the RDF flag
Yes
from 0 to 1 can also be
Read receive data in
SCFRDR2, and clear RDF
flag in SCFSR2 to 0
identified by an RXI interrupt.
3. Serial reception continuation
procedure: To continue serial
reception, read at least the
No
All data received?
receive trigger set number of
receive data bytes from
SCFRDR2, read 1 from the
Yes
RDF flag, then clear the RDF
flag to 0. The number of
Clear RE bit in SCSCR2 to 0
receive data bytes in
SCFRDR2 can be ascertained
End of reception
by reading the lower bits of
SCFDR2.
Figure 16.11 Sample Serial Reception Flowchart (1)
Rev. 3.0, 04/02, page 671 of 1064