• Bit 5—Transmit Enable (TE): Enables or disables the SCI serial transmitter.
Bit 5: TE
0
1
Description
Transmitter disabled (initial value). The transmit data register empty bit
(TDRE) in the serial status register (SSR) is locked at 1.
Transmitter enabled. Serial transmission starts when the transmit data
register empty (TDRE) bit in the serial status register (SSR) is cleared to
0 after writing of transmit data into the TDR. Select the transmit format
in the SMR before setting TE to 1.
• Bit 4—Receive Enable (RE): Enables or disables the SCI serial receiver.
Bit 4: RE
0
1
Description
Receiver disabled (initial value). Clearing RE to 0 does not affect the
receive flags (RDRF, FER, PER, ORER). These flags retain their
previous values.
Receiver enabled. Serial reception starts when a start bit is detected in
the asynchronous mode, or synchronous clock input is detected in the
clock synchronous mode. Select the receive format in the SMR before
setting RE to 1.
• Bit 3—Multiprocessor Interrupt Enable (MPIE): Enables or disables multiprocessor interrupts.
The MPIE setting is used only in the asynchronous mode, and only if the multiprocessor mode
bit (MP) in the serial mode register (SMR) is set to 1 during reception. The MPIE setting is
ignored in the clock synchronous mode or when the MP bit is cleared to 0.
Bit 3: MPIE
0
1
Description
Multiprocessor interrupts are disabled (normal receive operation) (initial
value). MPIE is cleared when the MPIE bit is cleared to 0, or the
multiprocessor bit (MPB) is set to 1 in receive data.
Multiprocessor interrupts are enabled. Receive-data-full interrupt
requests (RxI), receive-error interrupt requests (ERI), and setting of the
RDRF, FER, and ORER status flags in the serial status register (SSR)
are disabled until data with the multiprocessor bit set to 1 is received.
The SCI does not transfer receive data from the RSR to the RDR, does
not detect receive errors, and does not set the RDRF, FER, and ORER
flags in the serial status register (SSR). When it receives data that
includes MPB = 1, MPB is set to 1, and the SCI automatically clears
MPIE to 0, generates RxI and ERI interrupts (if the TIE and RIE bits in
the SCR are set to 1), and allows the FER and ORER bits to be set.
477