English
Language : 

SH7751 Datasheet, PDF (722/1224 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
15. Serial Communication Interface (SCI)
The bit rate error in asynchronous mode is found from the following equation:
Pck × 106
Error (%) = (N + 1) × B × 64 × 22n – 1 – 1 × 100
Table 15.3 shows sample SCBRR1 settings in asynchronous mode, and table 15.4 shows sample
SCBRR1 settings in synchronous mode.
Rev.4.00 Oct. 10, 2008 Page 624 of 1122
REJ09B0370-0400