9. Power-Down Modes
Example: To reduce the effect on FPSCR, arrange the following two instructions starting at
H'A0000000.
Address
H'A0000000
H'A0000002
:
Instruction String
FLDI1 FR0
FADD FR0, FR0 ; FLDI1 FR0 loads 1 into FR0,
:
; so the cause and flag bits of FPSCR are not set to 1.