14. Direct Memory Access Controller (DMAC)
6. Request queue transfer request acceptance
a. The DDT has four request queues for each of channels 1 to 3. When these request queues
are full, a DMA transfer request from an external device will be ignored.
b. If a DMA transfer request for channel 0 is input during execution of a channel 0 DMA bus
cycle, the DDT will ignore that request. Confirm that channel 0 DMA transfer has finished
(burst mode) or that a DMA bus cycle is not in progress (cycle steal mode).
7. DTR format
a. The DDT module processes DTR.ID, DTR.MD, and DTR.SZ as follows.
When DTR.ID= 00
• MD = 00, SZ ≠ 101, 110: Handshake protocol using the data bus
• MD ≠ 00, SZ = 111: CHCR0.DE = 0 setting (DMA transfer end request)
• MD = 10, SZ = 110: DDT request queue clear
When DTR.ID ≠ 00
• Transfer request to channels 1—3 (items other than ID ignored)
Note: Do not use setting values other than the above.
8. Data transfer end request
a. A data transfer end request (DTR.ID = 00, MD ≠ 00, SZ = 111) cannot be accepted during
channel 0 DMA transfer. Therefore, if edge detection and burst mode are set for channel 0,
transfer cannot be ended midway.
b. When a transfer end request (DTR.ID = 00, MD ≠ 00, SZ = 111) is accepted, the values set
in CHCR0, SAR0, DAR0, and DMATCR0 are retained. In this case, execution cannot be
restarted from an external device. To restart execution, set CHCR0.DE = 1 with an MOV
instruction.
9. Request queue clearance
a. When settings of DTR.ID = 00, DTR.MD = 10, and SZ = 110 are accepted by the DDT in
normal data transfer mode, DDT channel 0 requests and channel 1 to 3 request queues are
all cleared. All external requests held on the DMAC side are also cleared.
b. In case 3-c, the DMAC freeze state can be cleared.
c. When settings of DMAOR.DDT = 1, DTR.ID = 00, DTR.MD = 10, and SZ = 110 are
accepted by the DDT in case 11, the DMAC freeze state can be cleared.
10. DBREQ assertion
a. After DBREQ is asserted, do not assert DBREQ again until BAVL is asserted, as this will
result in a discrepancy between the number of DBREQ and BAVL assertions.
b. The BAVL assertion period due to DBREQ assertion is one cycle.
If a row address miss occurs in a read or write in the non-precharged bank during
synchronous DRAM access, BAVL is asserted for a number of cycles in accordance with
the RAS precharge interval set in BSC.MCR.TCP.