English
Language : 

SH7050 Datasheet, PDF (371/841 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperH RISC engine Family/
ATU settings
APC setting
Port setting
ATU setting
ATU setting
APC setting
Section 11 Advanced Pulse Controller (APC)
APC output operation
GR function selection
1
GR setting
2
Count operation setting
3
Interrupt request setting
4
Rise/fall port setting
5
Port output setting
6
Start count
7
Compare-match?
Yes
GR setting
Rise/fall port setting
No
8
9
Figure 11.3 Example of Setting Procedure for Advanced Pulse Controller Output
Operation
Example of Advanced Pulse Controller Output Operation: Figure 11.4 shows an example of
advanced pulse controller output operation.
1. Set ATU registers GR2A and GR2B (to be used for output trigger generation) as output
compare registers. Set the rise point in GR2A and the fall point in GR2B, and enable the
respective compare-match interrupts.
2. Write H'0101 to POPCR.
3. Start ATU timer 2. When a GR2A compare-match occurs, 1 is output from the PULS0 pin.
When a GR2B compare-match occurs, 0 is output from the PULS0 pin.
Rev. 5.00 Jan 06, 2006 page 351 of 818
REJ09B0273-0500