English
Language : 

SH7050 Datasheet, PDF (328/841 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperH RISC engine Family/
Section 10 Advanced Timer Unit (ATU)
OVF Setting Timing in Overflow: When TCNT overflows (from H'FFFF to H'0000, or from
H'FFFFFFFF to H'00000000), the OVF bit is set to 1 in the timer status register (TSR).
The timing in this case is shown in figure 10.32.
CK
TCNT input clock
TCNT H'FFFF
Overflow signal
H'0000
Interrupt status flag
OVF
Interrupt request signal
OVI
Figure 10.32 OVF Setting Timing in Overflow
Rev. 5.00 Jan 06, 2006 page 308 of 818