English
Language : 

SH7211 Datasheet, PDF (738/1228 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family
Section 15 Serial Communication Interface with FIFO (SCIF)
• Transmitting Serial Data (Clocked Synchronous Mode)
Figure 15.11 shows a sample flowchart for transmitting serial data.
Use the following procedure for serial data transmission after enabling the SCIF for transmission.
Start of transmission
Read TDFE flag in SCFSR
No
TDFE = 1?
Yes
Write transmit data to SCFTDR,
read TDFE and TEND flags in
SCFSR, and clear the TDRE and
[1]
TEND flags in SCFSR to 0
All data transmitted?
Yes
No
[2]
Read TEND flag in SCFSR
No
TEND = 1?
Yes
Clear TE bit in SCSCR to 0
[1] SCIF status check and transmit data
write:
Read SCFSR and check that the
TDFE flag is set to 1, then write
transmit data to SCFTDR, read 1
from the TDFE and TEND flags, and
clear these flags to 0.
[2] Serial transmission continuation
procedeure:
To continue serial transmission, read
1 from the TDFE flag to confirm that
writing is possible, them write data to
SCFTDR, and then clear the TDFE
flag to 0.
End of transmission
Figure 15.11 Sample Flowchart for Transmitting Serial Data
Rev. 2.00 May. 08, 2008 Page 714 of 1200
REJ09B0344-0200