English
Language : 

SH7211 Datasheet, PDF (611/1228 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family
Section 10 Multi-Function Timer Pulse Unit 2 (MTU2)
(19) Operation when Error Occurs during Phase Counting Mode Operation, and Operation
is Restarted in PWM Mode 2
Figure 10.153 shows an explanatory diagram of the case where an error occurs in phase counting
mode and operation is restarted in PWM mode 2 after re-setting.
1
2
RESET TMDR
(PCM)
3
4
5
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
6
Match
7
8
9
10
11
12
13
Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM2) (1 init (MTU2) (1)
0 out)
MTU2 module output
TIOC*A
Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 10.153 Error Occurrence in Phase Counting Mode, Recovery in PWM Mode 2
1 to 9 are the same as in figure 10.151.
10. Set PWM mode 2.
11. Initialize the pins with TIOR. (In PWM mode 2, the cycle register pins are not initialized.)
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
Rev. 2.00 May. 08, 2008 Page 587 of 1200
REJ09B0344-0200