EFM32WG Datasheet, PDF (602/834 Pages) List of Unclassifed Manufacturers – The EFM32WG Wonder Gecko is the ideal choice for demanding 8-, 16-, and 32-bit energy sensitive applications.
Figure 24.1. PCNT Overview
...the world's most energy friendly microcontrollers
CMU (consept ual)
LFACLK
Clock
sw it ch
PPCCNNTTnn__SS01IINN
S0PRS Input
CLKPCNT
In v er t er
In v er t er
Pulse Widt h
Filt er
Quadrat ure
decoder
Ed g e
detector
OVR_SINGLE
EXTCLK_SINGLE
1
EXTCLK_QUAD
CNT
Peripheral bus
TOP
TOPB
S1PRS Input
24.3.1 Pulse Counter Modes
The pulse counter can operate in single input oversampling mode (OVSSINGLE), externally clocked
single input counter mode (EXTCLKSINGLE) and externally clocked quadrature decoder mode
(EXTCLKQUAD). The following sections describe operation of each of the three modes and how they
are enabled. Input timing constraints are described in Section 24.3.5 (p. 605) and Section 24.3.6 (p.
605) .
24.3.1.1 Single Input Oversampling Mode
This mode is enabled by writing OVSSINGLE to the MODE field in the PCNTn_CTRL register and
disabled by writing DISABLE to the same field. LFACLK is configured from the registers in the Clock
Management Unit (CMU), Chapter 11 (p. 124) .
The optional pulse width filter is enabled by setting the FILT bit in the PCNTn_CTRL register. Additionally,
the PCNTn_S0IN input may be inverted, so that falling edges are counted, by setting the EDGE bit in
the PCNTn_CTRL register.
If S1CDIR is cleared, PCNTn_S0IN is the only observed input in this mode. The PCNTn_S0IN input
is sampled by the LFACLK and the number of detected positive or negative edges on PCNTn_S0IN
appears in PCNTn_CNT. The counter may be configured to count down by setting the CNTDIR bit in
PCNTn_CTRL. Default is to count up.
The counting direction can also be controlled externally in this mode by setting S1CDIR in PCNTn_CTRL.
This will make the input value on PCNTn_S1IN decide the direction counted on a PCNTn_S0IN edge.
If PCNTn_S1IN is high, the count is done according to CNTDIR in PCNTn_CTRL. If low, the count
direction is opposite.
24.3.1.2 Externally Clocked Single Input Counter Mode
This mode is enabled by writing EXTCLKSINGLE to the MODE field in the PCNTn_CTRL register and
disabled by writing DISABLE to the same field. The external pin clock source must be configured from
the registers in the CMU (Chapter 11 (p. 124) ).
Positive edges on PCNTn_S0IN are used to clock the counter. Similar to the oversampled mode,
PCNTn_S1IN is used to determine the count direction if S1CDIR in PCNTn_CTRL is set. If not, CNTDIR
in PCNTn_CTRL solely defines count direction. As the LFACLK is not used in this mode, the PCNT
module can operate in EM3.
2013-05-08 - Wonder Gecko Family - d0233_Rev0.50
602