Figure 20.1. TIMER Block Overview
HFPERCLKTIMERn
Pr e sc a l e r
TIMn _CC0
PRS input s
TIMn _CC1
PRS input s
TIMn _CC2
PRS input s
Input logic
Input logic
Input logic
Quadrat ure
Decoder
Ed g e
detect
Ed g e
detect
Ed g e
detect
...the world's most energy friendly microcontrollers
CNTCLK
Count er
control
Updat e
condition
TIMERn _CNT
TIMERn _TOP
=
=0
Input Capt ure
Not e: For sim plicit y, all
TIMERn_CCx regist ers are
grouped together in the figure,
but they all have individual Input
Capt ure Regist ers
Ov e r f l o w
Underflow
Com pare Mat ch x
TnTCnTICCMCR]ER0]R[1n1[ _51C:50C: 0x
===
Com pare and
PWM config
Com pare and
PWM config
Com pare and
PWM config
TIMn _CC0
TIMn _CC1
TIMn _CC2
20.3.1 Counter Modes
The Timer consists of a counter that can be configured to the following modes:
1. Up-count: Counter counts up until it reaches the value in TIMERn_TOP, where it is reset to 0 before
counting up again.
2. Down-count: The counter starts at the value in TIMERn_TOP and counts down. When it reaches 0,
it is reloaded with the value in TIMERn_TOP.
3. Up/Down-count: The counter starts at 0 and counts up. When it reaches the value in TIMERn_TOP,
it counts down until it reaches 0 and starts counting up again.
4. Quadrature Decoder: Two input channels where one determines the count direction, while the other
pin triggers a clock event.
In addition, to the TIMER modes listed above, the TIMER also supports a 2x Count Mode. In this mode
the counter increments/decrements by 2. The 2x Count Mode intended use is to generate 2x PWM
frequency when the Compare/Capture channel is put in PWM mode. The 2x Count Mode can be enabled
by setting the X2CNT bitfield in the TIMERn_CTRL register.
The counter value can be read or written by software at any time by accessing the CNT field in
TIMERn_CNT.
20.3.1.1 Events
Overflow is set when the counter value shifts from TIMERn_TOP to the next value when counting up. In
up-count mode the next value is 0. In up/down-count mode, the next value is TIMERn_TOP-1.
Underflow is set when the counter value shifts from 0 to the next value when counting down. In down-
count mode, the next value is TIMERn_TOP. In up/down-count mode the next value is 1.
Update event is set on overflow in up-count mode and on underflow in down-count or up/down count
mode. This event is used to time updates of buffered values.
20.3.1.2 Operation
Figure 20.2 (p. 522) shows the hardware Timer/Counter control. Software can start or stop the counter
by writing a 1 to the START or STOP bits in TIMERn_CMD. The counter value (CNT in TIMERn_CNT)
can always be written by software to any 16-bit value.
2013-05-08 - Wonder Gecko Family - d0233_Rev0.50