English
Language : 

EFM32WG Datasheet, PDF (209/834 Pages) List of Unclassifed Manufacturers – The EFM32WG Wonder Gecko is the ideal choice for demanding 8-, 16-, and 32-bit energy sensitive applications.
...the world's most energy friendly microcontrollers
Offset
0x0A0
0x0A4
Name
EBI_IFC
EBI_IEN
Type
W1
RW
Description
Interrupt Flag Clear Register
Interrupt Enable Register
14.5 Register Description
14.5.1 EBI_CTRL - Control Register
Offset
0x000
Reset
Access
Bit Position
Name
Bit
31
30
29:28
27
26
25
24
23
22
21
20
19
18
17
16
Name
Reset
Access Description
ALTMAP
0
RW
Alternative Address Map Enable
This field enables or disables the alternative (256 MB per bank) address map.
ITS
0
RW
Individual Timing Set, Line Polarity and Mode Definition Enable
This field enables or disables individual timing sets, line polarities and modes per bank.
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in Section 2.1 (p. 3)
BL3
0
RW
Byte Lane Enable for bank 3
Enables or disables the Byte Lane functionality for bank 3. Ignored when ITS = 0.
BL2
0
RW
Byte Lane Enable for bank 2
Enables or disables the Byte Lane functionality for bank 2. Ignored when ITS = 0.
BL1
0
RW
Byte Lane Enable for bank 1
Enables or disables the Byte Lane functionality for bank 1. Ignored when ITS = 0.
BL
0
RW
Byte Lane Enable for bank 0
Enables or disables the Byte Lane functionality for bank 0. Applies to all banks when ITS = 0. Applies to only bank 0 when ITS = 1.
ARDYTO3DIS
0
RW
ARDY Timeout Disable for bank 3
Enables or disables the ARDY timeout functionality for bank 3. The timeout value is 32 internal clock cycles. Ignored when ITS = 0.
ARDY3EN
0
RW
ARDY Enable for bank 3
Enables or disables the ARDY functionality for bank 3. Ignored when ITS = 0.
ARDYTO2DIS
0
RW
ARDY Timeout Disable for bank 2
Enables or disables the ARDY timeout functionality for bank 2. The timeout value is 32 internal clock cycles. Ignored when ITS = 0.
ARDY2EN
0
RW
ARDY Enable for bank 2
Enables or disables the ARDY functionality for bank 2. Ignored when ITS = 0.
ARDYTO1DIS
0
RW
ARDY Timeout Disable for bank 1
Enables or disables the ARDY timeout functionality for bank 1. The timeout value is 32 internal clock cycles. Ignored when ITS = 0.
ARDY1EN
0
RW
ARDY Enable for bank 1
Enables or disables the ARDY functionality for bank 1. Ignored when ITS = 0.
ARDYTODIS
0
RW
ARDY Timeout Disable
Enables or disables the ARDY timeout functionality. The timeout value is 32 internal clock cycles. Applies to all banks when ITS =
0. Applies to only bank 0 when ITS = 1.
ARDYEN
0
RW
ARDY Enable
Enables or disables the ARDY functionality. Applies to all banks when ITS = 0. Applies to only bank 0 when ITS = 1.
2013-05-08 - Wonder Gecko Family - d0233_Rev0.50
209