15. A/D Converter
15.4.3 Single-Cycle Scan Mode
In single-cycle scan mode , A/D conversion is to be performed once on the specified channels.
Operations are as follows.
1. When the ADST bit in ADCR is set to 1 by a software, MTU, or external trigger input, A/D
conversion starts on the channel with the lowest number in the group (AN0, AN1, ..., AN3).
2. When A/D conversion for each channel is completed, the result is sequentially transferred to
the A/D data register corresponding to each channel.
3. When conversion of all the selected channels is completed, the ADF bit in ADCSR is set to 1.
If the ADIE bit is set to 1 at this time, an ADI interrupt is requested after A/D conversion ends.
4. After A/D conversion ends, the ADST bit is automatically cleared to 0 and the A/D converter
enters the idle state. When the ADST bit is cleared to 0 during A/D conversion, A/D
conversion stops and the A/D converter enters the idle state.
15.4.4 Input Signal Sampling and A/D Conversion Time
The A/D converter has a built-in sample-and-hold circuit for each module. The A/D converter
samples the analog input when the A/D conversion start delay time (tD) has passed after the ADST
bit in ADCR is set to 1, then starts conversion. Figure 15.2 shows the A/D conversion timing.
Table 15.3 shows the A/D conversion time.
As indicated in figure 15.2, the A/D conversion time (tCONV) includes tD and the input sampling time
(tSPL). The length of tD varies depending on the timing of the write access to ADCR. The total
conversion time therefore varies within the ranges indicated in table 15.3.
In scan mode, the values given in table 15.3 apply to the first conversion time. The values given in
table 15.4 apply to the second and subsequent conversions.
Rev.4.00 Mar. 27, 2008 Page 550 of 882
REJ09B0108-0400