11. Multi-Function Timer Pulse Unit (MTU)
Operation when Error Occurs during PWM Mode 1 Operation, and Operation is Restarted
in Phase Counting Mode: Figure 11.94 shows an explanatory diagram of the case where an error
occurs in PWM mode 1 and operation is restarted in phase counting mode after re-setting.
1
2
3
RESET TMDR TOER
(PWM1) (1)
MTU module output
TIOC*A
4
TIOR
(1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
8
9
10
Match Error PFC TSTR
occurs (PORT) (0)
11
TMDR
(PCM)
12
TIOR
(1 init
0 out)
13 14
PFC TSTR
(MTU) (1)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
n=0 to 15
Figure 11.94 Error Occurrence in PWM Mode 1, Recovery in Phase Counting Mode
1 to 10 are the same as in figure 11.91.
11. Set phase counting mode.
12. Initialize the pins with TIOR.
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Note: Phase counting mode can only be set for channels 1 and 2, and therefore TOER setting is
not necessary.