English
Language : 

SH7206 Datasheet, PDF (781/1188 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Section 15 Serial Communication Interface with FIFO (SCIF)
Initial
Bit
Bit Name Value R/W Description
7, 6
RTRG[1:0] 00
R/W Receive FIFO Data Trigger
Set the quantity of receive data which sets the receive
data full (RDF) flag in the serial status register (SCFSR).
The RDF flag is set to 1 when the quantity of receive
data stored in the receive FIFO register (SCFRDR) is
increased more than the set trigger number shown
below.
• Asynchronous mode • Clocked synchronous mode
00: 1
00: 1
01: 4
01: 2
10: 8
10: 8
11: 14
11: 14
Note:
In clock synchronous mode, to transfer the
receive data using DMAC, set the receive trigger
number to 1. If set to other than 1, CPU must
read the receive data left in SCFRDR.
5, 4
TTRG[1:0] 00
R/W Transmit FIFO Data Trigger
Set the quantity of remaining transmit data which sets
the transmit FIFO data register empty (TDFE) flag in the
serial status register (SCFSR). The TDFE flag is set to 1
when the quantity of transmit data in the transmit FIFO
data register (SCFTDR) becomes less than the set
trigger number shown below.
00: 8 (8)*
01: 4 (12)*
10: 2 (14)*
11: 0 (16)*
Note: * Values in parentheses mean the number of
empty bytes in SCFTDR when the TDFE flag is
set to 1.
Rev. 3.00 Jun. 18, 2008 Page 757 of 1160
REJ09B0191-0300