English
Language : 

SH7206 Datasheet, PDF (680/1188 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Section 10 Multi-Function Timer Pulse Unit 2 (MTU2)
(27) Operation when Error Occurs during Reset-Synchronized PWM Mode Operation, and
Operation is Restarted in PWM Mode 1
Figure 10.161 shows an explanatory diagram of the case where an error occurs in reset-
synchronized PWM mode and operation is restarted in PWM mode 1 after re-setting.
MTU2 module output
1
2
3
4
5
6
RESET TOCR TMDR TOER PFC TSTR
(RPWM) (1) (MTU2) (1)
7
8
9
10
11
12
13
14
Match Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM1) (1 init (MTU2) (1)
0 out)
TIOC3A
TIOC3B
Not initialized (TIOC3B)
TIOC3D
Not initialized (TIOC3D)
Port output
PE8
High-Z
PE9
High-Z
PE11
High-Z
Figure 10.161 Error Occurrence in Reset-Synchronized PWM Mode,
Recovery in PWM Mode 1
1 to 10 are the same as in figure 10.160.
11. Set PWM mode 1. (MTU2 positive phase output is low, and negative phase output is high.)
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Rev. 3.00 Jun. 18, 2008 Page 656 of 1160
REJ09B0191-0300