Section 10 Multi-Function Timer Pulse Unit 2 (MTU2)
(2) Operation when Error Occurs during Normal Mode Operation, and Operation is
Restarted in PWM Mode 1
Figure 10.136 shows an explanatory diagram of the case where an error occurs in normal mode
and operation is restarted in PWM mode 1 after re-setting.
1
2
3
RESET TMDR TOER
(normal) (1)
MTU2 module output
TIOC*A
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
8
9
10 11 12 13 14
Match Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM1) (1 init (MTU2) (1)
0 out)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 10.136 Error Occurrence in Normal Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 10.135.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 1.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Rev. 3.00 Jun. 18, 2008 Page 631 of 1160
REJ09B0191-0300