English
Language : 

SH7206 Datasheet, PDF (682/1188 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Section 10 Multi-Function Timer Pulse Unit 2 (MTU2)
(29) Operation when Error Occurs during Reset-Synchronized PWM Mode Operation, and
Operation is Restarted in Reset-Synchronized PWM Mode
Figure 10.163 shows an explanatory diagram of the case where an error occurs in reset-
synchronized PWM mode and operation is restarted in reset-synchronized PWM mode after re-
setting.
1
2
3
4
5
6
7
8
9
10
11
12
13
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR PFC TSTR Match
(RPWM) (1) (MTU2) (1)
occurs (PORT) (0) (MTU2) (1)
MTU2 module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE8
PE9
PE11
High-Z
High-Z
High-Z
Figure 10.163 Error Occurrence in Reset-Synchronized PWM Mode,
Recovery in Reset-Synchronized PWM Mode
1 to 10 are the same as in figure 10.160.
11. Set MTU2 output with the PFC.
12. Operation is restarted by TSTR.
13. The reset-synchronized PWM waveform is output on compare-match occurrence.
Rev. 3.00 Jun. 18, 2008 Page 658 of 1160
REJ09B0191-0300