English
Language : 

SH7206 Datasheet, PDF (292/1188 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7200 Series
Section 8 Bus State Controller (BSC)
read in case of a 32-bit device, and 16 bits in case of a 16-bit device. When writing, only the WEn
signal for the byte to be written is asserted.
It is necessary to output the data that has been read using RD when a buffer is established in the
data bus. The RD/WR signal is in a read state (high output) when no access has been carried out.
Therefore, care must be taken when controlling the external data buffer, to avoid collision.
Figures 8.4 and 8.5 show the basic timings of normal space access. If the WM bit in CSnWCR is
cleared to 0, a Tnop cycle is inserted after the CSn space access to evaluate the external wait
(figure 8.4). If the WM bit in CSnWCR is set to 1, external waits are ignored and no Tnop cycle is
inserted (figure 8.5).
CKIO
T1
T2
Tnop
T1
T2
A25 to A0
CSn
RD/WR
Read
RD
D15 to D0
Write
WEn
D15 to D0
BS
DACKn *
WAIT
Note: * The waveform for DACKn is when active low is specified.
Figure 8.4 Continuous Access for Normal Space 1
Bus Width = 16 Bits, Longword Access, CSnWCR.WM Bit = 0
(Access Wait = 0, Cycle Wait = 0)
Rev. 3.00 Jun. 18, 2008 Page 268 of 1160
REJ09B0191-0300