Section 23 High-Performance User Debugging Interface (H-UDI)
23.5 Usage Notes
1. An H-UDI command, once set, will not be modified as long as another command is not set
again from the H-UDI. If the same command is to be set continuously, the command must be
set after a command (BYPASS mode, etc.) that does not affect chip operations is once set.
2. In software standby mode and H-UDI module standby state, all of the functions in the H-UDI
cannot be used. To retain the TAP status before and after standby mode, keep TCK high before
entering standby mode.
3. Regardless of whether the H-UDI is used, make sure to keep the TRST pin low at power-on to
initialize the H-UDI.
4. When the TDO change timing switch command is set and the TRST pin is asserted
immediately after and the RES pin is negated, the TDO change timing switch command may
be cleared. To prevent this, make sure to put 20 tcyc or more between the signal change timing
of the RES and TRST pins when the TDO change timing switch command is set.
For details, see section 23.4.3, TDO Output Timing.
5. When starting the TAP controller after the negation of the TRST pin, make sure to allow 200
ns or more after the negation.