English
Language : 

SH7641 Datasheet, PDF (719/1036 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH™ RISC engine Family / SH7641 Series
Section 18 Multi-Function Timer Pulse Unit (MTU)
(26) Operation when Error Occurs during Reset-Synchronous PWM Mode Operation, and
Operation is Restarted in Normal Mode
Figure 18.110 shows an explanatory diagram of the case where an error occurs in reset-
synchronous PWM mode and operation is restarted in normal mode after re-setting.
MTU module
output
TIOC3A
1
2
3
4
5
6
7
8
9
10 11 12 13 14
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TMDR TIOR PFC TSTR
(CPWM) (1) (MTU) (1)
occurs (PORT) (0) (normal) (1 init (MTU) (1)
0 out)
TIOC3B
TIOC3D
Port output
TIOC3A/PTE[7]
TIOC3B/PTE[6]
High-Z
High-Z
TIOC3D/PTE[4]
High-Z
Figure 18.110 Error Occurrence in Reset-Synchronous PWM Mode,
Recovery in Normal Mode
1. After a reset, MTU output is low and ports are in the high-impedance state.
2. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with
TOCR.
3. Set reset-synchronous PWM.
4. Enable channel 3 and 4 output with TOER.
5. Set MTU output with the PFC.
6. The count operation is started by TSTR.
7. The reset-synchronous PWM waveform is output on compare-match occurrence.
8. An error occurs.
9. Set port output with the PFC and output the inverse of the active level.
10. The count operation is stopped by TSTR. (MTU output becomes the reset-synchronous PWM
output initial value.)
11. Set normal mode. (MTU positive phase output is low, and negative phase output is high.)
12. Initialize the pins with TIOR.
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Rev. 4.00 Sep. 14, 2005 Page 669 of 982
REJ09B0023-0400