Section 18 Multi-Function Timer Pulse Unit (MTU)
(12) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in Reset-Synchronous PWM Mode
Figure 18.96 shows an explanatory diagram of the case where an error occurs in PWM mode 1
and operation is restarted in reset-synchronous PWM mode after re-setting.
MTU module
output
TIOC3A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
RESETTMDR TOER TIOR PFC TSTR Match Error PFC TSTR TMDR TIOR TIOR TOER TOCR TMDRTOER PFC TSTR
(PWM1) (1) (1 init (MTU) (1)
occurs(PORT) (0) (normal)(0 ini(tdisabled) (0)
(RPWM) (1) (MTU) (1)
0 out)
0 out)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
• Not initialized (TIOC3D)
Port output
TIOC3A/PTE[7]
TIOC3B/PTE[6]
TIOC3D/PTE[4]
High-Z
High-Z
High-Z
Figure 18.96 Error Occurrence in PWM Mode 1,
Recovery in Reset-Synchronous PWM Mode
1 to 14 are the same as in figure 18.95.
15. Select the reset-synchronous PWM output level and cyclic output enabling/disabling with
TOCR.
16. Set reset-synchronous PWM.
17. Enable channel 3 and 4 output with TOER.
18. Set MTU output with the PFC.
19. Operation is restarted by TSTR.
Rev. 4.00 Sep. 14, 2005 Page 655 of 982