English
Language : 

SH7641 Datasheet, PDF (715/1036 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer SuperH™ RISC engine Family / SH7641 Series
Section 18 Multi-Function Timer Pulse Unit (MTU)
(22) Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in PWM Mode 1
Figure 18.106 shows an explanatory diagram of the case where an error occurs in complementary
PWM mode and operation is restarted in PWM mode 1 after re-setting.
MTU module
output
TIOC3A
1
2
3
4
5
6
78
9 10 11 12 13 14
RESET TOCR TMDR TOER PFC TSTR Match Error PFC TSTR TMDR TIOR PFC TSTR
(CPWM) (1) (MTU) (1)
occurs (PORT) (0) (PWM1) (1 init (MTU) (1)
0 out)
TIOC3B
• Not initialized (TIOC3B)
TIOC3D
Port output
TIOC3A/PTE[7]
High-Z
• Not initialized (TIOC3D)
TIOC3B/PTE[6]
High-Z
TIOC3D/PTE[4]
High-Z
Figure 18.106 Error Occurrence in Complementary PWM Mode,
Recovery in PWM Mode 1
1 to 10 are the same as in figure 18.105.
11. Set PWM mode 1. (MTU output goes low.)
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Rev. 4.00 Sep. 14, 2005 Page 665 of 982
REJ09B0023-0400