Section 18 Multi-Function Timer Pulse Unit (MTU)
(14) Operation when Error Occurs during PWM Mode 2 Operation, and Operation is
Restarted in PWM Mode 1
Figure 18.98 shows an explanatory diagram of the case where an error occurs in PWM mode 2
and operation is restarted in PWM mode 1 after re-setting.
MTU module
output
TIOC*A
1
2
3
4
5
6
7
8
9
10 11
RESET TMDR TIOR PFC TSTR Match Error PFC TSTR TMDR TIOR
(PWM2) (1 init (MTU) (1)
occurs (PORT) (0) (PWM1) (1 init
0 out)
0 out)
• Not initialized (cycle register)
12 13
PFC TSTR
(MTU) (1)
TIOC*B
• Not initialized (TIOC*B)
Port output
TIOC*A/PTE[n]
High-Z
TIOC*B/PTE[n]
High-Z
n = 0 to 15
Figure 18.98 Error Occurrence in PWM Mode 2, Recovery in PWM Mode 1
1 to 9 are the same as in figure 18.97.
10. Set PWM mode 1.
11. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev. 4.00 Sep. 14, 2005 Page 657 of 982