English
Language : 

QG5000XSL9TH Datasheet, PDF (394/458 Pages) Intel Corporation – Intel 5000X Chipset Memory Controller Hub (MCH)
Functional Description
Table 5-31. Intel 5000X chipset Error List (Sheet 7 of 7)
ERR #
in MCH
Error Name
M17
Correctable
Non-Mirrored
Demand Data
ECC Error.
Definition
The MCH detected
correctable data.
M18
Correctable
Mirrored
Demand Data
ECC Error
The MCH detected
correctable data.
M19
Correctable
Spare-Copy
Data ECC Error
The MCH detected
correctable data from the
failing DIMM rank during a
sparing copy.
M20
Correctable
Patrol Data
ECC Error
During a patrol scrub, the
MCH detected correctable
data.
M21
FB-DIMM
Northbound
CRC error on
FB-DIMM Sync
Status
The MCH detected a
northbound CRC error on a
Sync Status
Error
Type
Corr
Corr
Corr
Corr
Corr
Log Register
FERR_NF_FBD
NERR_NF_FBD
RECMEM
REDMEM
CERRCNT
BADCNT
BADRANK
FERR_NF_FBD
NERR_NF_FBD
RECMEM
REDMEM
CERRCNT
BADCNT
BADRANK
FERR_NF_FBD
NERR_NF_FBD
RECMEM
REDMEM
CERRCNT
BADCNT
BADRANK
FERR_NF_FBD
NERR_NF_FBD
RECMEM
REDMEM
CERRCNT
BADCNT
BADRANK
FERR_NF_FBD
NERR_NF_FBD
RECFBD
M22
M27
M28
SPD protocol
Error
The MCH detected an SPD
interface error.
Corr
FERR_NF_FBD
NERR_NF_FBD
DIMM-Spare
Copy start
Triggered DIMM-Spare copy
DIMM-Spare DIMM-Spare copy
Copy complete completed normally
Corr
Corr
FERR_NF_FBD
NERR_NF_FBD
FERR_NF_FBD
NERR_NF_FBD
§
Cause / Actions
Correct the data in memory
and to the requestor.
Correct the data in memory
and to the requestor.
Correct the data in the spare
DIMM or the off-line branch.
Correct the data in memory.
Drop. If sync was issued to
prepare a fast reset for alert
recovery then replay any
queued configuration
command destined for an
alerting DIMM or a DIMM with
a corrupted status CRC.
WARNING: Possible double
DIMM configuration
command execution may
incur undesirable side-
effects.
Successive correction
attempts performed by
software.
Start DIMM-spare copy
No Action
394
Intel® 5000X Chipset Memory Controller Hub (MCH) Datasheet