Section 22 Electrical Characteristics
(3) Bus Timing
Table 22.7 Bus Timing
Condition A: VCC = 2.7 V to 3.6 V, AVCC = 2.7 V to 3.6 V, Vref = 2.7 V to AVCC, VSS = AVSS =
0 V, φ = 2 MHz to 20 MHz, Ta = –20°C to 75°C (regular specifications),
Ta = –40°C to 85°C (wide-range specifications)
Condition B: VCC = 3.0 V to 3.6 V, AVCC = 3.0 V to 3.6 V, Vref = 3.0 V to AVCC, VSS = AVSS =
0 V, φ = 2 MHz to 25 MHz, Ta = –20°C to 75°C (regular specifications),
Ta = –40°C to 85°C (wide-range specifications)
Item
Address delay time
Address setup time
Symbol
tAD
tAS
Address hold time
tAH
Precharge time*
tPCH
CS delay time 1
CS delay time 2*
CS delay time 3*
tCSD1
tCSD2
tCSD3
AS delay time
tASD
RD delay time 1
tRSD1
RD delay time 2
CAS delay time*
tRSD2
tCASD
Read data setup time tRDS
Read data hold time
tRDH
Read data access time 1 tACC1
Read data access time 2 tACC2
Read data access time 3 tACC3
Read data access time 4 tACC4
Read data access time 5 tACC5
Read data access time 6* tACC6
Condition A
Min
Max
—
20
0.5 × —
tcyc – 15
0.5 × —
tcyc – 10
1.5 × —
tcyc– 20
—
20
—
20
—
25
—
20
—
20
—
20
—
20
15
—
0
—
—
1.0 ×
tcyc – 25
—
1.5 ×
tcyc – 25
—
2.0 ×
tcyc – 25
—
2.5 ×
tcyc – 25
—
3.0 ×
tcyc – 25
—
1.0 ×
tcyc – 25
Condition B
Min
Max
—
20
0.5 × —
tcyc – 15
0.5 × —
tcyc – 8
1.5 × —
tcyc– 15
—
15
—
15
—
20
—
15
—
15
—
15
—
15
15
—
0
—
—
1.0 ×
tcyc – 20
—
1.5 ×
tcyc – 20
—
2.0 ×
tcyc – 20
—
2.5 ×
tcyc – 20
—
3.0 ×
tcyc – 20
—
1.0 ×
tcyc – 20
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Test Conditions
Figures 22.6 to
22.13
Rev.6.00 Sep. 27, 2007 Page 945 of 1268
REJ09B0220-0600