English
Language : 

D12320VF25IV Datasheet, PDF (516/1304 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Section 10 16-Bit Timer Pulse Unit (TPU)
10.4.2 Basic Functions
Counter Operation: When one of bits CST0 to CST5 is set to 1 in TSTR, the TCNT counter for
the corresponding channel starts counting. TCNT can operate as a free-running counter, periodic
counter, and so on.
• Example of count operation setting procedure
Figure 10.6 shows an example of the count operation setting procedure.
Operation selection
Select counter clock
[1]
Periodic counter
Select counter clearing source [2]
Select output compare register [3]
Set period
[4]
Start count
[5]
<Periodic counter>
Free-running counter
Start count
<Free-running counter>
[1] Select the counter
clock with bits
TPSC2 to TPSC0 in
TCR. At the same
time, select the
input clock edge
with bits CKEG1
and CKEG0 in TCR.
[2] For periodic counter
operation, select the
TGR to be used as
the TCNT clearing
source with bits
CCLR2 to CCLR0 in
TCR.
[3] Designate the TGR
selected in [2] as an
output compare
register by means of
TIOR.
[4] Set the periodic
counter cycle in the
TGR selected in [2].
[5] [5] Set the CST bit in
TSTR to 1 to start
the counter
operation.
Figure 10.6 Example of Counter Operation Setting Procedure
Rev.6.00 Sep. 27, 2007 Page 484 of 1268
REJ09B0220-0600