Section 14 Serial Communication Interface (SCI)
The BRR setting is found from the following formulas.
Asynchronous mode:
N=
φ
× 106 – 1
64 × 22n–1 × B
Synchronous mode:
N=
φ
× 106 – 1
8 × 22n–1 × B
Where B: Bit rate (bits/s)
N: BRR setting for baud rate generator (0 ≤ N ≤ 255)
φ: Operating frequency (MHz)
n: Baud rate generator input clock (n = 0 to 3)
(See the table below for the relation between n and the clock.)
SMR Setting
n
Clock
CKS1
CKS0
0
φ
0
0
1
φ/4
0
1
2
φ/16
1
0
3
φ/64
1
1
The bit rate error in asynchronous mode is found from the following formula:
φ × 106
Error (%) = {
– 1} × 100
(N + 1) × B × 64 × 22n–1
Rev.6.00 Sep. 27, 2007 Page 620 of 1268
REJ09B0220-0600