English
Language : 

EP4SE360F35I4 Datasheet, PDF (349/432 Pages) Altera Corporation – This section provides a complete overview of all features relating to the Stratix IV device family, which is the most architecturlly advanced
Chapter 10: Configuration, Design Security, and Remote System Upgrades in Stratix IV Devices
Fast Passive Parallel Configuration
10–13
Table 10–4. FPP Timing Parameters for Stratix IV Devices (Part 2 of 2) (Note 1), (2)
Minimum
Maximum
Symbol
Parameter
Stratix IV Stratix IV Stratix IV Stratix IV Stratix IV Stratix IV Units
(7)
(8)
(9)
(7)
(8)
(9)
tST2CK
nSTATUS high to first rising
edge of DCLK
2
—
s
tDSU
Data setup time before
rising edge on DCLK
4
—
ns
tDH
Data hold time after rising
edge on DCLK
1
—
ns
TR
Input rise time
—
t
Input fall time
—
40
ns
40
ns
tCD2UM
CONF_DONE high to user
mode (5)
55
150
s
tCD2CU
CONF_DONE high to CLKUSR
enabled
4 × maximum
DCLK period
—
—
tCD2UMC
CONF_DONE high to user
mode with CLKUSR option
on
tCD2CU + (8532 × CLKUSR
period)
—
—
tCH
DCLK high time (6)
3.6
4.5
5.6
—
ns
tCL
DCLK low time (6)
3.6
4.5
5.6
—
ns
tCLK
DCLK period (6)
8
10
12.5
—
ns
fMAX
DCLK frequency
—
125
100
80
MHz
Notes to Table 10–4:
(1) This information is preliminary.
(2) Use these timing parameters when you have not enabled the decompression and design security features.
(3) You can obtain this value if you do not delay the configuration by extending the nCONFIG or nSTATUS low pulse width.
(4) This value is applicable if you do not delay the configuration by externally holding nSTATUS low.
(5) The minimum and maximum numbers apply only if you chose the internal oscillator as the clock source for starting the device.
(6) Adding up tCH and tCL equals to tCLK. When EP4SE230 tCH is 3.6 ns (min), tCL must be 4.4 ns and vice versa.
(7) Applicable to EP4SE230, EP4SE360, EP4SGX70, EP4SGX110, EP4SGX180, EP4SGX230, EP4SGX290 (except F45 package), EP4SGX360 (except
F45 package), EP4S40G2, EP4S100G2 devices.
(8) Applicable to EP4SE530, EP4SGX290 (only for F45 package), EP4SGX360 (only for F45 package), EP4SGX530, EP4S40G5, EP4S100G3,
EP4S100G4, EP4S100G5 devices.
(9) Applicable to EP4SE820 only.
September 2012 Altera Corporation
Stratix IV Device Handbook
Volume 1