English
Language : 

EP4SE360F35I4 Datasheet, PDF (339/432 Pages) Altera Corporation – This section provides a complete overview of all features relating to the Stratix IV device family, which is the most architecturlly advanced
Chapter 10: Configuration, Design Security, and Remote System Upgrades in Stratix IV Devices
Configuration Schemes
10–3
Table 10–1. Configuration Schemes for Stratix IV Devices (Part 2 of 2)
Configuration Scheme
MSEL2
MSEL1
MSEL0
JTAG-based configuration (4)
(3)
(3)
(3)
Notes to Table 10–1:
(1) Stratix IV devices only support fast AS configuration. You must use either EPCS64 or EPCS128 devices to configure a Stratix IV device in fast
AS mode.
(2) These modes are only supported when using a MAX II device or a microprocessor with flash memory for configuration. In these modes, the
host system must output a DCLK that is ×4 the data rate.
(3) Do not leave the MSEL pins floating, connect them to VCCPGM or GND. These pins support the non-JTAG configuration scheme used in
production. If you only use the JTAG configuration, connect the MSEL pins to GND.
(4) The JTAG-based configuration takes precedence over other configuration schemes, which means the MSEL pin settings are ignored. The
JTAG-based configuration does not support the design security or decompression features.
Table 10–2 lists the uncompressed raw binary file (.rbf) configuration file sizes for
Stratix IV devices.
Table 10–2. Uncompressed Raw Binary File (.rbf) Sizes for Stratix IV Devices
Device
EP4SE230
EP4SE360
EP4SE530
EP4SE820
EP4SGX70
EP4SGX110
EP4SGX180
EP4SGX230
EP4SGX290
EP4SGX360
EP4SGX530
EP4S40G2
EP4S40G5
EP4S100G2
EP4S100G3
EP4S100G4
EP4S100G5
Note to Table 10–2:
(1) This only applies to the F45 package.
Data Size (Bits)
94,557,472
128,395,584
171,722,064
241,684,472
47,833,352
47,833,352
94,557,472
94,557,472
128,395,584
171,722,064 (1)
128,395,584
171,722,064 (1)
171,722,064
94,557,472
171,722,064
94,557,472
171,722,064
171,722,064
171,722,064
Use the data in Table 10–2 to estimate the file size before design compilation. Different
configuration file formats; for example, a hexidecimal (.hex) or tabular text file (.ttf)
format, have different file sizes. Refer to the Quartus® II software for the different
types of configuration file and file sizes. However, for any specific version of the
Quartus II software, any design targeted for the same device has the same
uncompressed configuration file size. If you are using compression, the file size can
vary after each compilation because the compression ratio depends on the design.
September 2012 Altera Corporation
Stratix IV Device Handbook
Volume 1