English
Language : 

EP4SE360F35I4 Datasheet, PDF (338/432 Pages) Altera Corporation – This section provides a complete overview of all features relating to the Stratix IV device family, which is the most architecturlly advanced
10–2
Chapter 10: Configuration, Design Security, and Remote System Upgrades in Stratix IV Devices
Configuration Schemes
■ “Configuration Data Decompression” on page 10–47
■ “Remote System Upgrades” on page 10–49
■ “Remote System Upgrade Mode” on page 10–53
■ “Dedicated Remote System Upgrade Circuitry” on page 10–56
■ “Quartus II Software Support” on page 10–62
■ “Design Security” on page 10–63
Configuration Devices
Altera® serial configuration devices support a single-device and multi-device
configuration solution for Stratix IV devices and are used in the fast AS configuration
scheme. Serial configuration devices offer a low-cost, low pin-count configuration
solution.
f For information about serial configuration devices, refer to the Serial Configuration
Devices (EPCS1, EPCS4, EPCS16, EPCS64, and EPCS128) Data Sheet in volume 2 of the
Configuration Handbook.
1 All minimum timing information in this chapter covers the entire Stratix IV family.
Some devices may work at less than the minimum timing stated in this handbook due
to process variation.
Configuration Schemes
Select the configuration scheme by driving the Stratix IV device MSEL pins either high
or low, as shown in Table 10–1. The MSEL input buffers are powered by the VCC power
supply. Altera recommends hard wiring the MSEL[] pins to VCCPGM and GND. The
MSEL[2..0] pins have 5-k internal pull-down resistors that are always active.
During power-on reset (POR) and during reconfiguration, the MSEL pins must be at
VIL and VIH levels of VCCPGM voltage to be considered logic low and logic high.
1 To avoid problems with detecting an incorrect configuration scheme, hardwire the
MSEL[] pins to VCCPGM and GND without pull-up or pull-down resistors. Do not drive
the MSEL[] pins by a microprocessor or another device.
Table 10–1. Configuration Schemes for Stratix IV Devices (Part 1 of 2)
Configuration Scheme
MSEL2
Fast passive parallel
0
Passive serial
0
Fast AS (40 MHz) (1)
0
Remote system upgrade fast AS (40 MHz) (1)
0
FPP with design security feature and/or decompression enabled (2)
0
MSEL1
0
1
1
1
0
MSEL0
0
0
1
1
1
Stratix IV Device Handbook