EP4SE360F35I4 Datasheet, PDF (338/432 Pages) Altera Corporation – This section provides a complete overview of all features relating to the Stratix IV device family, which is the most architecturlly advanced | |||
|
◁ |
10â2
Chapter 10: Configuration, Design Security, and Remote System Upgrades in Stratix IV Devices
Configuration Schemes
â âConfiguration Data Decompressionâ on page 10â47
â âRemote System Upgradesâ on page 10â49
â âRemote System Upgrade Modeâ on page 10â53
â âDedicated Remote System Upgrade Circuitryâ on page 10â56
â âQuartus II Software Supportâ on page 10â62
â âDesign Securityâ on page 10â63
Configuration Devices
Altera® serial configuration devices support a single-device and multi-device
configuration solution for Stratix IV devices and are used in the fast AS configuration
scheme. Serial configuration devices offer a low-cost, low pin-count configuration
solution.
f For information about serial configuration devices, refer to the Serial Configuration
Devices (EPCS1, EPCS4, EPCS16, EPCS64, and EPCS128) Data Sheet in volume 2 of the
Configuration Handbook.
1 All minimum timing information in this chapter covers the entire Stratix IV family.
Some devices may work at less than the minimum timing stated in this handbook due
to process variation.
Configuration Schemes
Select the configuration scheme by driving the Stratix IV device MSEL pins either high
or low, as shown in Table 10â1. The MSEL input buffers are powered by the VCC power
supply. Altera recommends hard wiring the MSEL[] pins to VCCPGM and GND. The
MSEL[2..0] pins have 5-kï internal pull-down resistors that are always active.
During power-on reset (POR) and during reconfiguration, the MSEL pins must be at
VIL and VIH levels of VCCPGM voltage to be considered logic low and logic high.
1 To avoid problems with detecting an incorrect configuration scheme, hardwire the
MSEL[] pins to VCCPGM and GND without pull-up or pull-down resistors. Do not drive
the MSEL[] pins by a microprocessor or another device.
Table 10â1. Configuration Schemes for Stratix IV Devices (Part 1 of 2)
Configuration Scheme
MSEL2
Fast passive parallel
0
Passive serial
0
Fast AS (40 MHz) (1)
0
Remote system upgrade fast AS (40 MHz) (1)
0
FPP with design security feature and/or decompression enabled (2)
0
MSEL1
0
1
1
1
0
MSEL0
0
0
1
1
1
Stratix IV Device Handbook
Volume 1