English
Language : 

EP4SE360F35I4 Datasheet, PDF (208/432 Pages) Altera Corporation – This section provides a complete overview of all features relating to the Stratix IV device family, which is the most architecturlly advanced
6–34
Chapter 6: I/O Features in Stratix IV Devices
OCT Calibration
Table 6–11. OCT Calibration Block Counts and Placement in Stratix IV Devices (5A through 8C) (Part 2 of 2)
Device
EP4SGX110
EP4SGX180
EP4SGX230
EP4SGX290
EP4SGX360
EP4SGX530
EP4S40G2
EP4S40G5
EP4S100G2
EP4S100G3
EP4S100G4
EP4S100G5
Pin
780
1152
780
1152
1517
780
1152
1517
780
1152
1517
1760
1932
780
1152
1517
1760
1932
1152
1517
1760
1932
1517
1517
1517
1932
1932
1517
1932
Number of
Bank
OCT Blocks 5A 5B 5C 6A 6B 6C 7A 7B 7C 8A 8B 8C
8
—————— Y — N Y — N
8
——— Y — N Y — N Y — N
8
—————— Y — N Y — N
8
——— Y — N Y N N Y Y N
8
Y—N Y—N Y N N Y N N
8
—————— Y — N Y — N
8
——— Y — N Y N N Y Y N
8
Y—N Y—N Y N N Y N N
8
—————— Y — N Y — N
8
——— Y — N Y N N Y N N
8
Y—N Y—N Y N N Y N N
8
Y—N Y—N Y N N Y N N
10
Y—N Y N N Y N N Y N Y
8
—————— Y — N Y — N
8
——— Y — N Y N N Y N N
8
Y—N Y—N Y N N Y N N
8
Y—N Y—N Y N N Y N N
10
Y—N Y N N Y N N Y N Y
8
——— Y — N Y N N Y N Y
10
Y—N Y—N Y N N Y N Y
10
Y—N Y—N Y N N Y N Y
10
Y N N Y—N Y N N Y N Y
8
Y—N Y—N Y N N Y N N
10
Y—N Y—N Y N N Y N Y
8
Y—N Y—N Y N N Y N N
10
Y N N Y—N Y N N Y N Y
10
Y N N Y—N Y N N Y N Y
10
Y—N Y—N Y N N Y N Y
10
Y N N Y—N Y N N Y N Y
Sharing an OCT Calibration Block on Multiple I/O Banks
An OCT calibration block has the same VCCIO as the I/O bank that contains the block.
OCT RS calibration is supported on all I/O banks with different VCCIO voltage
standards, up to the number of available OCT calibration blocks. You can configure
the I/O banks to receive calibration codes from any OCT calibration block with the
same VCCIO. All I/O banks with the same VCCIO can share one OCT calibration block,
even if that particular I/O bank has an OCT calibration block.
Stratix IV Device Handbook
Volume 1
September 2012 Altera Corporation