EP2AGX95EF29C6N Datasheet, PDF (337/380 Pages) Altera Corporation – Device Interfaces and Integration | |||
|
◁ |
Chapter 9: Configuration, Design Security, and Remote System Upgrades in Arria II Devices
Remote System Upgrades
9â51
Enabling Remote Update
You can enable remote update for Arria II devices in the Quartus II software before
design compilation (in the Compiler Settings menu). In remote update mode, the
auto-restart configuration after error option is always enabled. To enable remote
update in the projectâs compiler settings, follow these steps:
1. On the Assignment menu, click Device. The Settings dialog box appears.
2. Click Device and Pin Options. The Device and Pin Options dialog box appears.
3. Click the Configuration tab.
4. From the Configuration scheme list, select Active Serial (you can also use
Configuration Device) (Figure 9â23).
5. From the Configuration Mode list, select Remote (Figure 9â23).
6. Click OK.
7. In the Settings dialog box, click OK.
Figure 9â23. Enabling Remote Update in the Compiler Settings Menu for Arria II Devices
July 2012 Altera Corporation
Arria II Device Handbook Volume 1: Device Interfaces and Integration
|
▷ |