EP2AGX95EF29C6N Datasheet, PDF (186/380 Pages) Altera Corporation – Device Interfaces and Integration
6–22
Chapter 6: I/O Features in Arria II Devices
OCT Support
You can enable the left-shift series termination control feature in the ALTIOBUF
megafunction in the Quartus II software. The Quartus II software only allows
left-shift series termination control for 25- calibrated RS OCT with 50- external
reference resistors connected to the RUP and RDN pins. You can only use left-shift series
termination control for the I/O standards that support 25- calibrated RS OCT.
1 This feature is automatically enabled if you are using a bidirectional I/O with 25-
calibrated RS OCT and 50- RT OCT.
f For more information about how to enable the left-shift series termination feature in
the ALTIOBUF megafunction, refer to the I/O Buffer (ALTIOBUF) Megafunction User
Guide.
Expanded RS OCT with Calibration for Arria II GZ Devices
OCT calibration circuits always adjust RS OCT to match the external resistors
connected to the RUP and RDN pin; however, it is possible to achieve RS OCT values
other than the 25- and 50- resistors. Theoretically, if you need a different RS OCT
value, you can change the resistance connected to the RUP and RDN pins accordingly.
Practically, the RS OCT range that Arria II GZ devices support is limited because of
output buffer size and granularity limitations.
The Quartus II software only allows discrete RS OCT calibration settings of 25, 40, 50,
and 60  . You can select the closest discrete value of RS OCT with calibration settings
in the Quartus II software to your system to achieve the closest timing. For example, if
you are using 20- RS OCT with calibration in your system, you can select the 25-
RS OCT with calibration setting in the Quartus II software to achieve the closest
timing.
Table 6–12 lists expanded RS OCT with calibration supported in Arria II devices. Use
expanded RS OCT with calibration of SSTL and HSTL for impedance matching to
improve signal integrity but do not use it to meet the JEDEC standard.
Table 6–12. Selectable I/O Standards with Expanded RS OCT with Calibration Range for Arria II GZ
Devices
I/O Standard
3.3-V LVTTL/LVCMOS
2.5-V LVTTL/LVCMOS
1.8-V LVTTL/LVCMOS
1.5-V LVTTL/LVCMOS
1.2-V LVTTL/LVCMOS
SSTL-2
SSTL-18
SSTL-15
HSTL-18
HSTL-15
HSTL-12
Expanded RS OCT Range
Row I/O ()
Column I/O ()
20–60
20–60
20–60
20–60
20–60
20–60
40–60
20–60
40–60
20–60
20–60
20–60
20–60
20–60
40–60
20–60
20–60
20–60
40–60
20–60
40–60
20–60
Arria II Device Handbook Volume 1: Device Interfaces and Integration