English
Language : 

SH7750_08 Datasheet, PDF (799/1162 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer
Section 15 Serial Communication Interface (SCI)
Figure 15.22 shows an example of SCI operation in reception.
Transfer
direction
Serial clock
Serial data
Bit 7 Bit 0
Bit 7 Bit 0 Bit 1
Bit 6 Bit 7
RDRF
ORER
RXI interrupt
request
Data read from
SCRDR1 and RDRF
flag cleared to 0 in RXI
interrupt handler
RXI interrupt
request
One frame
ERI interrupt
request due to
overrun error
Figure 15.22 Example of SCI Receive Operation
Simultaneous Serial Data Transmission and Reception (Synchronous Mode): Figure 15.23
shows a sample flowchart for simultaneous serial transmit and receive operations.
Use the following procedure for simultaneous serial data transmit and receive operations after
enabling the SCI for transmission and reception.
Rev.7.00 Oct. 10, 2008 Page 715 of 1074
REJ09B0366-0700