English
Language : 

S912XHZ512F1VAG Datasheet, PDF (595/978 Pages) Freescale Semiconductor, Inc – Covers MC9S12XHZ384, MC9S12XHZ256
Chapter 15 Serial Communication Interface (S12SCIV5)
Enable single-wire operation by setting the LOOPS bit and the receiver source bit, RSRC, in SCI control
register 1 (SCICR1). Setting the LOOPS bit disables the path from the RXD pin to the receiver. Setting
the RSRC bit connects the TXD pin to the receiver. Both the transmitter and receiver must be enabled
(TE = 1 and RE = 1).The TXDIR bit (SCISR2[1]) determines whether the TXD pin is going to be used as
an input (TXDIR = 0) or an output (TXDIR = 1) in this mode of operation.
NOTE
In single-wire operation data from the TXD pin is inverted if RXPOL is set.
15.4.8 Loop Operation
In loop operation the transmitter output goes to the receiver input. The RXD pin is disconnected from the
SCI.
Transmitter
TXD
Receiver
RXD
Figure 15-31. Loop Operation (LOOPS = 1, RSRC = 0)
Enable loop operation by setting the LOOPS bit and clearing the RSRC bit in SCI control register 1
(SCICR1). Setting the LOOPS bit disables the path from the RXD pin to the receiver. Clearing the RSRC
bit connects the transmitter output to the receiver input. Both the transmitter and receiver must be enabled
(TE = 1 and RE = 1).
NOTE
In loop operation data from the transmitter is not recognized by the receiver
if RXPOL and TXPOL are not the same.
15.5 Initialization/Application Information
15.5.1 Reset Initialization
See Section 15.3.2, “Register Descriptions”.
15.5.2 Modes of Operation
15.5.2.1 Run Mode
Normal mode of operation.
To initialize a SCI transmission, see Section 15.4.5.2, “Character Transmission”.
MC9S12XHZ512 Data Sheet, Rev. 1.06
Freescale Semiconductor
595