English
Language : 

S912XHZ512F1VAG Datasheet, PDF (588/978 Pages) Freescale Semiconductor, Inc – Covers MC9S12XHZ384, MC9S12XHZ256
Chapter 15 Serial Communication Interface (S12SCIV5)
To determine the value of a data bit and to detect noise, recovery logic takes samples at RT8, RT9, and
RT10. Table 15-18 summarizes the results of the data bit samples.
Table 15-18. Data Bit Recovery
RT8, RT9, and RT10 Samples
000
001
010
011
100
101
110
111
Data Bit Determination
0
0
0
1
0
1
1
1
Noise Flag
0
1
1
1
1
1
1
0
NOTE
The RT8, RT9, and RT10 samples do not affect start bit verification. If any
or all of the RT8, RT9, and RT10 start bit samples are logic 1s following a
successful start bit verification, the noise flag (NF) is set and the receiver
assumes that the bit is a start bit (logic 0).
To verify a stop bit and to detect noise, recovery logic takes samples at RT8, RT9, and RT10. Table 15-19
summarizes the results of the stop bit samples.
Table 15-19. Stop Bit Recovery
RT8, RT9, and RT10 Samples
000
001
010
011
100
101
110
111
Framing Error Flag
1
1
1
0
1
0
0
0
Noise Flag
0
1
1
1
1
1
1
0
MC9S12XHZ512 Data Sheet, Rev. 1.06
588