SH7080 Datasheet, PDF (715/1644 Pages) Renesas Technology Corp – 32-Bit RISC Microcomputer SuperH™ RISC engine Family
Section 11 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during PWM Mode 2 Operation, and Operation is Restarted
in Phase Counting Mode: Figure 11.152 shows an explanatory diagram of the case where an
error occurs in PWM mode 2 and operation is restarted in phase counting mode after re-setting.
MTU2 module output
TIOC*A
1
2
3
4
5
RESET TMDR TIOR PFC TSTR
(PWM2) (1 init (MTU2) (1)
0 out)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11
12
13
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
Not initialized (cycle register)
TIOC*B
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 11.152 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode
1 to 9 are the same as in figure 11.149.
10. Set phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU2 output with the PFC.
13. Operation is restarted by TSTR.
Rev. 3.00 May 17, 2007 Page 657 of 1582
REJ09B0181-0300