English
Language : 

HD6417706 Datasheet, PDF (460/709 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer Super RISC engine Family/SH7700 Series
This processing can be interrupted. When the TIE bit is set to 1 and interrupt requests are enabled,
a transmit-data-empty interrupt (TXI) will be requested when the TEND flag is set to 1 at the end
of the transmission. When the RIE bit is set to 1 and interrupt requests are enabled, a
communication error interrupt (ERI) will be requested when the ERS flag is set to 1 when an error
occurs in transmission. See Interrupt Operation below for more information.
Start
Initialize
Start transmission
No
FER/ERS = 0?
Yes
No
TEND = 1?
Yes
Write transmit data in SCTDR
and clear TDRE
flag in SCSSR to 0
No
All data transmitted?
Yes
No
FER/ERS = 0?
Yes
No
TEND = 1?
Yes
Clear TE bit in SCSCR to 0
Error processing
Error processing
End transmission
Figure 15.6 Transmission Flowchart
Serial Data Reception: The processing procedures in the smart card mode are the same as in
ordinary SCI processing. The reception processing flowchart is shown in figure 15.7.
Rev. 4.00, 03/04, page 414 of 660